No. | Test Item | Test Method | Result |
1 | Fire Resistatnce Test | - | No bubbles,rupture,crack on the surface |
2 | Flexural Strength | ASTM D790-10 Method A | 12200psi |
Flexural Modulus | 2350000psi | ||
3 | Density | ASTM D792-13 Method B | 133.8lb/ft3 |
4 | High Temperature Resistance Test | - | No bubbles,rupture,deformation on the surface |
Advantages :
Heat Resistance : ONUS’s worktop can resist 262℃ , it won’t foam and crack, the fire can extinguish because it has no any of paper materials.
Reagents Resistance : ONUS’s product can resist many of chemical reagents, it won’t been corrode by the most of chemicals.
Durability : ONUS products are monolithic and non-porous, it cannot delaminate or swell
Molded : The molded marine edge is easy to clean and install for user, due to the smoothly and non-porous surface, it won’t hidden bacteria and guarantee the worktops have long life.
Physical Test :
Application:
Epoxy resin worktops are use in all kinds of laboratories. In view of the rigid request for laboratory, epoxy resin worktops are vey popular in laboratory industry, it is the best choice for lab staff. The laboratory include the following:
Length (mm) | Width (mm) | thickness (mm) |
990 | 760 | 25 |
1290 | 760 | 25 |
1590 | 760 | 25 |
1530 | 816 | 25 |
1830 | 816 | 25 |
2190 | 760 | 25 |